The ISO 80369-3 standard covers the whole enteral system, except reservoir connectors which is covered by ISO18250-2. This part of ISO 80369 includes the interface dimensions and requirements for the design and functional performance of small-bore connectors for use on enteral medical devices and accessories.
The ISO 80369-3 standard includes performance tests following the methods of the ISO 80369-20 standard. Enersol has the reference connectors and the test equipment needed for the performance tests (ISO 80369-20).
Enersol can supply its reference connectors and test equipment, or for early stage testing/small lot testing this can be performed by Enersol in its ISO 17025 accredited laboratory.
Click the BUTTON below to download guidance documents for Enersol Reference Connectors and Equipment needed for the performance tests of ISO 80369-20.
Guidance document for testing Enteral Connectors
Enersol's reference connectors have been designed specifically to meet requirements of ISO 80369-3.
(Cat. # S63) ISO 80369-3 Figure C.1 Female reference connector (Cat. # S65) ISO 80369-3 Figure C.3 Male reference connector
(Cat. # S64) ISO 80369-3 Figure C.2 Female reference connector (Cat. # S66) ISO 80369-3 Figure C.4 Male reference connectorEnersol's reference connectors are made from stainless steel and have been designed to be used with Enersol testing equipment and devices. On request, Enersol can supply adapters to fit the reference connectors to machines other than Enersol's.
The reference connectors have a hex grip area with 10mm flats (for use in Enersol test equipment). The hex grip has an internal M5 thread. On request, reference connectors can be made to order with threads other than M5 either internal or external, as requested. Alternatively, adapters can be supplied to convert to a different thread type.
Reference connectors that are used for leakage tests are shipped with push-in fittings for use with 4mm hoses, making them fast and easy to use with Enersol testing equipment.
Provided with the reference connectors are individual display boxes and long-form calibration certificates by an ISO 17025 accredited calibration laboratory (at no extra cost or lead).
Enersol has a full range of equipment for the tests in ISO 80369-20 and ISO 80369-3. Please see the ISO 80369-20 page, which you can visit here.
To find out more, please contact Enersol by emailing or submitting a request for catalogue.
For pricing information and lead times, please contact Enersol. Lead times vary and rely on order size and stock on-hand. The price per unit improves with bulk purchases of 3 or more units of the same reference connector.
Contact Enersol for information by Email Online request for catalogue or pricing
Sydney (head) office Phone | +61 2 9552 1707
Penang office Phone | +60 4 281 1371
Sydney (head) office address
235 Nelson Street, Annandale, NSW 2038 AUSTRALIA
Google Map - Enersol AU
Penang office address
No. 2-2, Lebuh Sungai Pinang 1, Seksyen 8,
Bandar Georgetown, Daerah Timur Laut,
11600 Pulau Pinang, MALAYSIA
Google Map - ENERSOL MY
For general enquiries please contact enquiries@enersol.com.au
For Laboratory equipment and
testing enquiries please contact
Lisa Henretty or
Hung Truong